CBQ-L磁力管道离心泵

CQB-L型磁力泵型号意义
| 1 | 泵壳 | 2 | 叶轮 |
5 | 隔离套 | 6 | 止推环 | |
3 | 密封环 | 4 | 轴承体 | |
7 | 轴承 | 8 | 轴套 | |
11 | 螺母 | 12 | 联接架 | |
9 | 轴 | 10 | 内磁钢总成 | |
13 | 外磁钢总成 | 14 | 电机 |
型号 | 进出口经 (mm) | 流量 (m3/h) | 扬程 (m) | 电极功率 (kw) |
25-125 | 25 | 4 | 20 | 1.5 |
25-160 | | 4 | 32 | 2.2 |
40-125 | 40 | 6.3 | 20 | 2.2 |
40-160 | 6.3 | 32 | 3 | |
40-200 | 6.3 | 50 | 5.5 | |
40-250 | 6.3 | 80 | 11 | |
50-100 | 50 | 12.5 | 12.5 | 1.5 |
50-125 | 12.5 | 20 | 3 | |
50-160 | 12.5 | 32 | 4 | |
50-200 | 12.5 | 50 | 7.5 | |
50-250 | 12.5 | 80 | 15 | |
65-100 | 65 | 25 | 12.5 | 2.2 |
65-125 | 25 | 20 | 4 | |
65-160 | 25 | 32 | 5.5 | |
65-200 | 25 | 50 | 11 | |
65-250 | 25 | 80 | 18.5 | |
80-100 | 80 | 50 | 12.5 | 4 |
80-125 | 50 | 20 | 7.5 | |
80-160 | 50 | 32 | 11 | |
80-200 | 50 | 50 | 18.5 | |
80-250 | 50 | 80 | 30 | |
100-100 | 100 | 100 | 12.5 | 75 |
100-125 | 100 | 20 | 15 | |
100-160 | 100 | 32 | 18.5 | |
100-200 | 100 | 50 | 30 | |
100-250 | 100 | 80 | 45 | |
125-125 | 125 | 160 | 20 | 18.5 |
125-160 | 160 | 32 | 30 | |
125-200 | 160 | 50 | 45 | |
125-250 | 160 | 80 | 75 |
CQB-L型磁力泵的故障原因及排除方法
故障现象 | 原 因 分 析 | 排 除 方 法 |
泵不出水 | 1、 水泵反转 2、 进水管漏气 3、 泵腔储水不足 4、 电压太高、启动时联轴器打滑 5、 吸程太高 6、 阀门没有打开 | 1、 调整电机旋转方向 2、 杜绝漏气 3、 增加储水量 4、 调整电压 5、 降低泵安装位置 6、 校正或改变阀门 |
流量不足 | 1、 吸入管径大小或堵塞 2、 叶轮流道阻塞 3、 扬程过高 4、 转速不够 | 1、 调换或清洗进水管 2、 清洗叶轮 3、 开大出水阀 4、 恢复额定转速 |
扬程过低 | 1、 流量过大 2、 转速太低 | 1、 关小出水阀 2、 恢复额定转速 |
澡音太大 | 1、 泵轴严重磨损 2、 轴承严重磨损 3、 外磁钢或内磁钢与隔离套接触 4、 密封环与叶轮研磨 5、 冷却箱内滚动轴承磨损 | 1、 更换泵轴 2、 更换轴承 3、 拆除泵头重新组装 4、 更换止推环、密封环 5、 更换滚动轴承 |
漏液 | 1、 O型密封圈损坏 | 1、 更换O型密封圈 |